Humidity Measurements in Cold and Humid Environments - Boundary-Layer Meteorology
- ️Laakso, Timo
- ️Fri Jul 01 2005
Abstract
Recent studies have shed new light on humidity conditions in the polar atmospheric boundary layer, and cast doubt on the reliability of humidity measurements above the frost point humidity. These issues are addressed herein by considering the processes that affect humidity and its measurement in cold climate conditions and by analyzing observations from two sites, at which the relative humidity is frequently above 100% at sub-freezing temperatures, as shown by repeatedly observed in-cloud icing events. Humidity measurements were made at these two sites by the commonly used Vaisala HMP35 probe and HMP233 capacitance probes respectively and simultaneously by the same manufacturer’s HMP243 probe that determines the frost point by a heated capacitance sensor. The results confirm that the relative humidity is frequently well above the frost point, both due to radiative cooling and to the advection of moist air, and that the conventional humidity measurements are unable to detect these events. Furthermore, after such events, the iced sensors show too high a humidity. The false values occur due to ice growth on the probe and cannot be corrected by any algorithm. Our results indicate that these problems, inherent to conventional humidity measurements in cold and humid environments, are avoided by the use of HMP243, which has a heated humidity probe.
Access this article
Subscribe and save
- Get 10 units per month
- Download Article/Chapter or eBook
- 1 Unit = 1 Article or 1 Chapter
- Cancel anytime
Buy Now
Price excludes VAT (USA)
Tax calculation will be finalised during checkout.
Instant access to the full article PDF.
Similar content being viewed by others
References
P.S. Anderson (1994) ArticleTitleA Method for Rescaling Humidity Sensors at Temperatures Well below Freezing J. Atmos. Oceanic. Tech. 11 1388–1391
P.S. Anderson (1996) ArticleTitleA Reply J. Atmos. Oceanic Tech. 13 913–914
Andreas, E. L., Guest, P. S., Persson, P. O. G., Fairall, C. W., Horst, T. W., Moriz, R. E. Semmer, S. R. (2002). Near-Surface Water Vapor over Polar Sea Ice is Always near Ice Saturation. J. Geophys. Res. 107: doi 10.1029/2000JC000411.
Anon: (2002). ATD SHEBA ISFF Flux-PAM Project Report, Appendix A: Laboratory Tests on RH Measurement by Capacitance Sensors at the Frost Point’, National Center for Atmospheric Research, http://www.atd.ucar.edu/rtf/projects/sheba/ rh.lo.T.isff.html.
S.J Dery M. Stieglitz (2002) ArticleTitleA Note on Surface Humidity Measurements in the Cold Canadian Environment Boundary-Layer Meteorol. 102 491–497
T.D Hewson N.J. Gait (1992) ArticleTitleHoar-Frost Deposition on Roads Meteorol. Mag. 121 1–21
J.C King P.S. Anderson (1999) ArticleTitleA Humidity Climatology for Halley, Antarctica based on Frost-Point Hygrometer Measurements Antarctic Sci. 11 100–104
R.W. Lindsay (1998) ArticleTitleTemporal Variability of Energy Balance of Thick Arctic Pack ice J. Climate. 11 313–333
L. Makkonen (1992) ArticleTitleAnalysis of Rotating Multicylinder Data in Measuring Cloud-Droplet Size and Liquid Water Content J. Atmos. Oceanic Tech. 9 258–263
L. Makkonen (1996) ArticleTitleComments on “A Method for Rescaling Humidity Sensors at Temperatures Well below Freezing” J. Atmos. Oceanic Tech. 13 911–912
L. Makkonen T. Laakso M. Marjaniemi K.J. Finstad (2001) ArticleTitleModelling and Prevention of Ice Accretion on Wind Turbines Wind Eng. 25 3–21
L. Makkonen P. Lehtonen L. Helle (2001b) ArticleTitleAnemometry in Icing Conditions J. Atmos. Oceanic Tech. 18 1457–1469
L.M. Miloshevich H. Vomel A. Paukkunen A.J. Heymsfield S.J. Oltmans (2001) ArticleTitleCharacterization and Correction of Relative Humidity Measurements from Vaisala RS80-A Radiosondes at Cold Temperatures J. Atmos. Oceanic Tech. 18 135–155
B Na R.L. Webb (2003) ArticleTitleA Fundamental Understanding of Factors Affecting Frost Nucleation Int. J. Heat Mass Transfer. 46 3797–3808 Occurrence Handle1:CAS:528:DC%2BD3sXltFKltbk%3D
T Ranta-aho L. Stormbom (2002) Real Time Measurement Using the Warmed Sensor Head Method. 4th International Symposium on Humidity and Moisture ISHM Taipei 583–588
J. Ström R. Busen M. Quante B. Guillemet P.R.A. Brown J. Heintzenberg (1994) ArticleTitlePre-EUCREX Intercomparison of Airborne Humidity Measuring Instruments J. Atmos. Oceanic Tech. 11 1392–1399
J. Tennermann (1999) ArticleTitleThe Chilled Mirror Dew Point Hygrometer as a Measurement Standard Sensors. 16 49–54
G.J.W. Visscher (1995) ArticleTitleStandard Psychrometers: A Matter of (P)references Meas. Sci. Tech. 6 1451–1461 Occurrence Handle1:CAS:528:DyaK2MXos12js7Y%3D
J. Wang H.L. Cole D.J. Carlson E.R. Miller K. Beierle A. Paukkunen T.K. Laine (2002) ArticleTitleCorrections for Humidity Measurement Errors from the Vaisala RS80 Radiosonde – Application to TOGA COARE Data J. Atmos. Oceanic Tech. 19 981–1002
Wang, J., Carlson, D. J., Parsons, D. B., Hock, T. F., Lauritsen, D., Cole, H. L., Beierle, K. Chamberlain, E. (2003). Performance of Operational Radiosonde Humidity Sensors in Direct Comparison with a Chilled Mirror Dew-point Hygrometer and its Climate Implication. Geophys. Res. Lett. 30: doi:10.1029/2003GL016985.
Author information
Authors and Affiliations
Technical Research Centre of Finland, Box 1805, Kemistintie 3, Espoo, 02044, VTT, Finland
Lasse Makkonen & Timo Laakso
Authors
- Lasse Makkonen
You can also search for this author inPubMed Google Scholar
- Timo Laakso
You can also search for this author inPubMed Google Scholar
Corresponding author
Correspondence to Lasse Makkonen.
Rights and permissions
About this article
Cite this article
Makkonen, L., Laakso, T. Humidity Measurements in Cold and Humid Environments. Boundary-Layer Meteorol 116, 131–147 (2005). https://doi.org/10.1007/s10546-004-7955-y
Received: 18 November 2004
Issue Date: July 2005
DOI: https://doi.org/10.1007/s10546-004-7955-y