The use of X-ray scattering techniques to determine corneal ultrastructure - PubMed
Review
The use of X-ray scattering techniques to determine corneal ultrastructure
K M Meek et al. Prog Retin Eye Res. 2001 Jan.
Abstract
The manner in which X-rays are scattered or diffracted by the cornea provides us with valuable insights into the fine structure of the corneal stroma. This is because when X-rays pass through a cornea a diffraction pattern is formed due to scattering from regularly arranged collagen molecules and fibrils that comprise the bulk of the stromal matrix. Collagen provides the cornea with most of its strength, and its proper organisation is believed to be important for tissue transparency. Ever since 1978, when the first X-ray diffraction patterns were obtained from the cornea using radiation from a powerful synchrotron source, biophysicists have recorded and analysed a huge number of X-ray diffraction patterns from many different corneas. This article aims to explain the ideas that underpin our use of X-ray diffraction to investigate corneal ultrastructure, and show how the knowledge gained to date has far-reaching implications for tissue biomechanics, disease changes and transparency.
Similar articles
-
Meek KM, Boote C. Meek KM, et al. Prog Retin Eye Res. 2009 Sep;28(5):369-92. doi: 10.1016/j.preteyeres.2009.06.005. Epub 2009 Jul 3. Prog Retin Eye Res. 2009. PMID: 19577657 Review.
-
X-Ray Diffraction Imaging of Corneal Ultrastructure.
Meek KM, Quantock AJ, Hayes S, Bell J. Meek KM, et al. Methods Mol Biol. 2020;2145:231-247. doi: 10.1007/978-1-0716-0599-8_16. Methods Mol Biol. 2020. PMID: 32542611
-
Rawe IM, Leonard DW, Meek KM, Zabel RW. Rawe IM, et al. Cornea. 1997 May;16(3):369-76. Cornea. 1997. PMID: 9143815
-
An x-ray diffraction investigation of corneal structure in lumican-deficient mice.
Quantock AJ, Meek KM, Chakravarti S. Quantock AJ, et al. Invest Ophthalmol Vis Sci. 2001 Jul;42(8):1750-6. Invest Ophthalmol Vis Sci. 2001. PMID: 11431438
-
Corneal structure and transparency.
Meek KM, Knupp C. Meek KM, et al. Prog Retin Eye Res. 2015 Nov;49:1-16. doi: 10.1016/j.preteyeres.2015.07.001. Epub 2015 Jul 2. Prog Retin Eye Res. 2015. PMID: 26145225 Free PMC article. Review.
Cited by
-
Changes in the refractive index of the stroma and its extrafibrillar matrix when the cornea swells.
Meek KM, Dennis S, Khan S. Meek KM, et al. Biophys J. 2003 Oct;85(4):2205-12. doi: 10.1016/S0006-3495(03)74646-3. Biophys J. 2003. PMID: 14507686 Free PMC article.
-
Tropocollagen springs allow collagen fibrils to stretch elastically.
Bell JS, Hayes S, Whitford C, Sanchez-Weatherby J, Shebanova O, Terrill NJ, Sørensen TLM, Elsheikh A, Meek KM. Bell JS, et al. Acta Biomater. 2022 Apr 1;142:185-193. doi: 10.1016/j.actbio.2022.01.041. Epub 2022 Jan 23. Acta Biomater. 2022. PMID: 35081430 Free PMC article.
-
Material properties of the posterior human sclera.
Grytz R, Fazio MA, Girard MJ, Libertiaux V, Bruno L, Gardiner S, Girkin CA, Downs JC. Grytz R, et al. J Mech Behav Biomed Mater. 2014 Jan;29:602-17. doi: 10.1016/j.jmbbm.2013.03.027. Epub 2013 Apr 20. J Mech Behav Biomed Mater. 2014. PMID: 23684352 Free PMC article.
-
Interfibrillar packing of bovine cornea by table-top and synchrotron scanning SAXS microscopy.
Sibillano T, De Caro L, Scattarella F, Scarcelli G, Siliqi D, Altamura D, Liebi M, Ladisa M, Bunk O, Giannini C. Sibillano T, et al. J Appl Crystallogr. 2016 Jul 14;49(Pt 4):1231-1239. doi: 10.1107/S1600576716010396. eCollection 2016 Aug 1. J Appl Crystallogr. 2016. PMID: 27504077 Free PMC article.
-
Effects of Thickness on Corneal Biomechanical Properties Using Optical Coherence Elastography.
Vantipalli S, Li J, Singh M, Aglyamov SR, Larin KV, Twa MD. Vantipalli S, et al. Optom Vis Sci. 2018 Apr;95(4):299-308. doi: 10.1097/OPX.0000000000001193. Optom Vis Sci. 2018. PMID: 29561496 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources