A multicapillary inlet jet disruption electrodynamic ion funnel interface for improved sensitivity using atmospheric pressure ion sources - PubMed
- ️Mon Jan 01 2001
. 2001 Sep 1;73(17):4162-70.
doi: 10.1021/ac010174e.
Affiliations
- PMID: 11569805
- DOI: 10.1021/ac010174e
A multicapillary inlet jet disruption electrodynamic ion funnel interface for improved sensitivity using atmospheric pressure ion sources
T Kim et al. Anal Chem. 2001.
Abstract
A new multicapillary inlet and ion funnel interface for electrospray ionization-mass spectrometry has been developed and demonstrated to achieve higher ion transmission efficiency compared to a single-capillary inlet and ion funnel interface. Even though the distance between the end of the ESI inlet capillary and the exit of the ion funnel (10 cm) is significantly longer than that of the conventional interface (typically a few millimeters), a significant part of the directed inlet gas flow persists into the first stage of pumping and results in an increased gas load to the second chamber. A jet disrupter made of a circular metal disk placed on axis in the ion funnel enhanced the dispersion of the directed gas flow from a multicapillary inlet and was also found to improve the ion transmission. The ion funnel with the jet disrupter demonstrated a 15% improvement in ion transmission (compared to that without the jet disrupter) and simultaneously reduced the pumping speed required for the first or second stage by a factor of 2-3. Compared to the sensitivity with the standard mass spectrometer interface (an API 3000, Sciex, Concord, ON, Canada) in MS/MS operation using an interface equipped with the jet disrupter and ion funnel, a 5.3-10.7-fold enhancement in signal was observed for samples with concentrations of 100-500 pg/microL and 10.2 to 14.1-fold enhancement for concentrations of 10 to 50 pg/microL. The decreased enhancement at higher concentrations is attributed to space charge effects and detector saturation.
Similar articles
-
Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.
Ibrahim Y, Tang K, Tolmachev AV, Shvartsburg AA, Smith RD. Ibrahim Y, et al. J Am Soc Mass Spectrom. 2006 Sep;17(9):1299-305. doi: 10.1016/j.jasms.2006.06.005. Epub 2006 Jul 12. J Am Soc Mass Spectrom. 2006. PMID: 16839773 Free PMC article.
-
Tang K, Tolmachev AV, Nikolaev E, Zhang R, Belov ME, Udseth HR, Smith RD. Tang K, et al. Anal Chem. 2002 Oct 15;74(20):5431-7. doi: 10.1021/ac0202583. Anal Chem. 2002. PMID: 12403604
-
Kim T, Udseth HR, Smith RD. Kim T, et al. Anal Chem. 2000 Oct 15;72(20):5014-9. doi: 10.1021/ac0003549. Anal Chem. 2000. PMID: 11055723
-
Chen LC, Ninomiya S, Hiraoka K. Chen LC, et al. J Mass Spectrom. 2016 Jun;51(6):396-411. doi: 10.1002/jms.3779. J Mass Spectrom. 2016. PMID: 27270863 Review.
-
Gas chromatography coupled to atmospheric pressure ionization mass spectrometry (GC-API-MS): review.
Li DX, Gan L, Bronja A, Schmitz OJ. Li DX, et al. Anal Chim Acta. 2015 Sep 3;891:43-61. doi: 10.1016/j.aca.2015.08.002. Epub 2015 Aug 13. Anal Chim Acta. 2015. PMID: 26388363 Review.
Cited by
-
Tang K, Shvartsburg AA, Lee HN, Prior DC, Buschbach MA, Li F, Tolmachev AV, Anderson GA, Smith RD. Tang K, et al. Anal Chem. 2005 May 15;77(10):3330-9. doi: 10.1021/ac048315a. Anal Chem. 2005. PMID: 15889926 Free PMC article.
-
Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.
Ibrahim Y, Tang K, Tolmachev AV, Shvartsburg AA, Smith RD. Ibrahim Y, et al. J Am Soc Mass Spectrom. 2006 Sep;17(9):1299-305. doi: 10.1016/j.jasms.2006.06.005. Epub 2006 Jul 12. J Am Soc Mass Spectrom. 2006. PMID: 16839773 Free PMC article.
-
Hossain M, Kaleta DT, Robinson EW, Liu T, Zhao R, Page JS, Kelly RT, Moore RJ, Tang K, Camp DG 2nd, Qian WJ, Smith RD. Hossain M, et al. Mol Cell Proteomics. 2011 Feb;10(2):M000062-MCP201. doi: 10.1074/mcp.M000062-MCP201. Epub 2010 Apr 21. Mol Cell Proteomics. 2011. PMID: 20410378 Free PMC article.
-
Draper BE, Anthony SN, Jarrold MF. Draper BE, et al. J Am Soc Mass Spectrom. 2018 Nov;29(11):2160-2172. doi: 10.1007/s13361-018-2038-3. Epub 2018 Aug 15. J Am Soc Mass Spectrom. 2018. PMID: 30112619
-
Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.
Ibrahim Y, Belov ME, Tolmachev AV, Prior DC, Smith RD. Ibrahim Y, et al. Anal Chem. 2007 Oct 15;79(20):7845-52. doi: 10.1021/ac071091m. Epub 2007 Sep 13. Anal Chem. 2007. PMID: 17850113 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous