Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation - PubMed
- ️Wed Jan 01 1992
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation
K K Kwong et al. Proc Natl Acad Sci U S A. 1992.
Abstract
Neuronal activity causes local changes in cerebral blood flow, blood volume, and blood oxygenation. Magnetic resonance imaging (MRI) techniques sensitive to changes in cerebral blood flow and blood oxygenation were developed by high-speed echo planar imaging. These techniques were used to obtain completely noninvasive tomographic maps of human brain activity, by using visual and motor stimulus paradigms. Changes in blood oxygenation were detected by using a gradient echo (GE) imaging sequence sensitive to the paramagnetic state of deoxygenated hemoglobin. Blood flow changes were evaluated by a spin-echo inversion recovery (IR), tissue relaxation parameter T1-sensitive pulse sequence. A series of images were acquired continuously with the same imaging pulse sequence (either GE or IR) during task activation. Cine display of subtraction images (activated minus baseline) directly demonstrates activity-induced changes in brain MR signal observed at a temporal resolution of seconds. During 8-Hz patterned-flash photic stimulation, a significant increase in signal intensity (paired t test; P less than 0.001) of 1.8% +/- 0.8% (GE) and 1.8% +/- 0.9% (IR) was observed in the primary visual cortex (V1) of seven normal volunteers. The mean rise-time constant of the signal change was 4.4 +/- 2.2 s for the GE images and 8.9 +/- 2.8 s for the IR images. The stimulation frequency dependence of visual activation agrees with previous positron emission tomography observations, with the largest MR signal response occurring at 8 Hz. Similar signal changes were observed within the human primary motor cortex (M1) during a hand squeezing task and in animal models of increased blood flow by hypercapnia. By using intrinsic blood-tissue contrast, functional MRI opens a spatial-temporal window onto individual brain physiology.
Similar articles
-
Menon RS, Ogawa S, Kim SG, Ellermann JM, Merkle H, Tank DW, Ugurbil K. Menon RS, et al. Invest Radiol. 1992 Dec;27 Suppl 2:S47-53. doi: 10.1097/00004424-199212002-00009. Invest Radiol. 1992. PMID: 1468875
-
Magnetic resonance imaging mapping of brain function. Human visual cortex.
Belliveau JW, Kwong KK, Kennedy DN, Baker JR, Stern CE, Benson R, Chesler DA, Weisskoff RM, Cohen MS, Tootell RB, et al. Belliveau JW, et al. Invest Radiol. 1992 Dec;27 Suppl 2(0 2):S59-65. doi: 10.1097/00004424-199212002-00011. Invest Radiol. 1992. PMID: 1468876 Free PMC article.
-
Functional magnetic resonance imaging of primary visual processing using a 1.0 Tesla scanner.
Lundervold A, Ersland L, Gjesdal KI, Smievoll AI, Tillung T, Sundberg H, Hugdahl K. Lundervold A, et al. Int J Neurosci. 1995 Apr;81(3-4):151-68. doi: 10.3109/00207459509004883. Int J Neurosci. 1995. PMID: 7628907 Review.
-
Functional magnetic resonance imaging of the human brain: data acquisition and analysis.
Turner R, Howseman A, Rees GE, Josephs O, Friston K. Turner R, et al. Exp Brain Res. 1998 Nov;123(1-2):5-12. doi: 10.1007/s002210050538. Exp Brain Res. 1998. PMID: 9835386 Review.
Cited by
-
Luber B, Steffener J, Tucker A, Habeck C, Peterchev AV, Deng ZD, Basner RC, Stern Y, Lisanby SH. Luber B, et al. Sleep. 2013 Jun 1;36(6):857-71. doi: 10.5665/sleep.2712. Sleep. 2013. PMID: 23729929 Free PMC article. Clinical Trial.
-
Keller JB, Hedden T, Thompson TW, Anteraper SA, Gabrieli JD, Whitfield-Gabrieli S. Keller JB, et al. Cortex. 2015 Mar;64:271-80. doi: 10.1016/j.cortex.2014.12.001. Epub 2014 Dec 13. Cortex. 2015. PMID: 25562175 Free PMC article.
-
Liu X, Duyn JH. Liu X, et al. Proc Natl Acad Sci U S A. 2013 Mar 12;110(11):4392-7. doi: 10.1073/pnas.1216856110. Epub 2013 Feb 25. Proc Natl Acad Sci U S A. 2013. PMID: 23440216 Free PMC article. Clinical Trial.
-
Larmor frequency shift from magnetized cylinders with arbitrary orientation distribution.
Sandgaard AD, Shemesh N, Kiselev VG, Jespersen SN. Sandgaard AD, et al. NMR Biomed. 2023 Mar;36(3):e4859. doi: 10.1002/nbm.4859. Epub 2022 Nov 28. NMR Biomed. 2023. PMID: 36285793 Free PMC article.
-
ULTRAHIGH FIELD and ULTRAHIGH RESOLUTION fMRI.
Uğurbil K. Uğurbil K. Curr Opin Biomed Eng. 2021 Jun;18:100288. doi: 10.1016/j.cobme.2021.100288. Epub 2021 Apr 14. Curr Opin Biomed Eng. 2021. PMID: 33987482 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources