Automated identification and quantification of protein phosphorylation sites by LC/MS on a hybrid triple quadrupole linear ion trap mass spectrometer - PubMed
Automated identification and quantification of protein phosphorylation sites by LC/MS on a hybrid triple quadrupole linear ion trap mass spectrometer
Brian L Williamson et al. Mol Cell Proteomics. 2006 Feb.
Free article
Abstract
Complete phosphorylation mapping of protein kinases was successfully undertaken using an automated LC/MS/MS approach. This method uses the direct combination of triple quadrupole and ion trapping capabilities in a hybrid triple quadrupole linear ion trap to selectively identify and sequence phosphorylated peptides. In particular, the use of a precursor ion scan of m/z -79 in negative ion mode followed by an ion trap high resolution scan (an enhanced resolution scan) and a high sensitivity MS/MS scan (enhanced product ion scan) in positive mode is a very effective method for identifying phosphorylation sites in proteins at low femtomole levels. Coupling of this methodology with a stable isotope N-terminal labeling strategy using iTRAQtrade mark reagents enabled phosphorylation mapping and relative protein phosphorylation levels to be determined between the active and inactive forms of the protein kinase MAPKAPK-1 in the same LC/MS run.
Similar articles
-
Stone J. Stone J. Methods Mol Biol. 2016;1383:133-51. doi: 10.1007/978-1-4939-3252-8_16. Methods Mol Biol. 2016. PMID: 26660183
-
Marquet P, Saint-Marcoux F, Gamble TN, Leblanc JC. Marquet P, et al. J Chromatogr B Analyt Technol Biomed Life Sci. 2003 Jun 5;789(1):9-18. doi: 10.1016/s1570-0232(03)00071-0. J Chromatogr B Analyt Technol Biomed Life Sci. 2003. PMID: 12726839
-
Patel DN, Li L, Kee CL, Ge X, Low MY, Koh HL. Patel DN, et al. J Pharm Biomed Anal. 2014 Jan;87:176-90. doi: 10.1016/j.jpba.2013.04.037. Epub 2013 May 6. J Pharm Biomed Anal. 2014. PMID: 23721687 Review.
-
Jansen R, Lachatre G, Marquet P. Jansen R, et al. Clin Biochem. 2005 Apr;38(4):362-72. doi: 10.1016/j.clinbiochem.2004.11.003. Clin Biochem. 2005. PMID: 15766737 Review.
Cited by
-
Jiang H, Sherwood R, Zhang S, Zhu X, Liu Q, Graeff R, Kriksunov IA, Lee HC, Hao Q, Lin H. Jiang H, et al. Anal Biochem. 2013 Feb 15;433(2):218-26. doi: 10.1016/j.ab.2012.10.029. Epub 2012 Oct 31. Anal Biochem. 2013. PMID: 23123429 Free PMC article.
-
Douglas P, Cui X, Block WD, Yu Y, Gupta S, Ding Q, Ye R, Morrice N, Lees-Miller SP, Meek K. Douglas P, et al. Mol Cell Biol. 2007 Mar;27(5):1581-91. doi: 10.1128/MCB.01962-06. Epub 2006 Dec 11. Mol Cell Biol. 2007. PMID: 17158925 Free PMC article.
-
Synchronized dual-polarity electrospray ionization mass spectrometry.
Chen HK, Chang CK, Wu CC, Huang MC, Wang YS. Chen HK, et al. J Am Soc Mass Spectrom. 2009 Dec;20(12):2254-7. doi: 10.1016/j.jasms.2009.08.014. Epub 2009 Aug 28. J Am Soc Mass Spectrom. 2009. PMID: 19775909
-
Dissanayake K, Toth R, Blakey J, Olsson O, Campbell DG, Prescott AR, MacKintosh C. Dissanayake K, et al. Biochem J. 2011 Feb 1;433(3):515-25. doi: 10.1042/BJ20101562. Biochem J. 2011. PMID: 21087211 Free PMC article.
-
Spycher C, Miller ES, Townsend K, Pavic L, Morrice NA, Janscak P, Stewart GS, Stucki M. Spycher C, et al. J Cell Biol. 2008 Apr 21;181(2):227-40. doi: 10.1083/jcb.200709008. Epub 2008 Apr 14. J Cell Biol. 2008. PMID: 18411308 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources