A calibration method for quantitative BOLD fMRI based on hyperoxia
Peter A Chiarelli et al. Neuroimage. 2007.
Abstract
The estimation of changes in CMR(O2) using functional MRI involves an essential calibration step using a vasoactive agent to induce an isometabolic change in CBF. This calibration procedure is performed most commonly using hypercapnia as the isometabolic stimulus. However, hypercapnia possesses a number of detrimental side effects. Here, a new method is presented using hyperoxia to perform the same calibration step. This procedure requires independent measurement of Pa(O2), the BOLD signal, and CBF. We demonstrate that this method yields results that are comparable to those derived using other methods. Further, the hyperoxia technique is able to provide an estimate of the calibration constant that has lower overall intersubject and intersession variability compared to the hypercapnia approach.
Similar articles
-
Wise RG, Harris AD, Stone AJ, Murphy K. Wise RG, et al. Neuroimage. 2013 Dec;83:135-47. doi: 10.1016/j.neuroimage.2013.06.008. Epub 2013 Jun 13. Neuroimage. 2013. PMID: 23769703 Free PMC article. Clinical Trial.
-
Englund EK, Fernández-Seara MA, Rodríguez-Soto AE, Lee H, Rodgers ZB, Vidorreta M, Detre JA, Wehrli FW. Englund EK, et al. J Cereb Blood Flow Metab. 2020 Jul;40(7):1501-1516. doi: 10.1177/0271678X19867276. Epub 2019 Aug 8. J Cereb Blood Flow Metab. 2020. PMID: 31394960 Free PMC article.
-
Quantitative fMRI using hyperoxia calibration: reproducibility during a cognitive Stroop task.
Goodwin JA, Vidyasagar R, Balanos GM, Bulte D, Parkes LM. Goodwin JA, et al. Neuroimage. 2009 Aug 15;47(2):573-80. doi: 10.1016/j.neuroimage.2009.04.064. Epub 2009 May 3. Neuroimage. 2009. PMID: 19398018
-
Blockley NP, Griffeth VE, Simon AB, Buxton RB. Blockley NP, et al. NMR Biomed. 2013 Aug;26(8):987-1003. doi: 10.1002/nbm.2847. Epub 2012 Sep 4. NMR Biomed. 2013. PMID: 22945365 Free PMC article. Review.
-
Physiology of functional magnetic resonance imaging: energetics and function.
Kida I, Hyder F. Kida I, et al. Methods Mol Med. 2006;124:175-95. doi: 10.1385/1-59745-010-3:175. Methods Mol Med. 2006. PMID: 16506422 Review.
Cited by
-
Lajoie I, Tancredi FB, Hoge RD. Lajoie I, et al. PLoS One. 2016 Sep 20;11(9):e0163071. doi: 10.1371/journal.pone.0163071. eCollection 2016. PLoS One. 2016. PMID: 27649493 Free PMC article.
-
The Relationship Between M in "Calibrated fMRI" and the Physiologic Modulators of fMRI.
Lu H, Hutchison J, Xu F, Rypma B. Lu H, et al. Open Neuroimag J. 2011;5:112-9. doi: 10.2174/1874440001105010112. Epub 2011 Nov 4. Open Neuroimag J. 2011. PMID: 22276083 Free PMC article.
-
Quantitative measurement of cerebral physiology using respiratory-calibrated MRI.
Bulte DP, Kelly M, Germuska M, Xie J, Chappell MA, Okell TW, Bright MG, Jezzard P. Bulte DP, et al. Neuroimage. 2012 Mar;60(1):582-91. doi: 10.1016/j.neuroimage.2011.12.017. Epub 2011 Dec 22. Neuroimage. 2012. PMID: 22209811 Free PMC article.
-
A comparison of physiologic modulators of fMRI signals.
Liu P, Hebrank AC, Rodrigue KM, Kennedy KM, Park DC, Lu H. Liu P, et al. Hum Brain Mapp. 2013 Sep;34(9):2078-88. doi: 10.1002/hbm.22053. Epub 2012 Mar 28. Hum Brain Mapp. 2013. PMID: 22461234 Free PMC article.
-
From a Demand-Based to a Supply-Limited Framework of Brain Metabolism.
Herculano-Houzel S, Rothman DL. Herculano-Houzel S, et al. Front Integr Neurosci. 2022 Apr 1;16:818685. doi: 10.3389/fnint.2022.818685. eCollection 2022. Front Integr Neurosci. 2022. PMID: 35431822 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical