pubmed.ncbi.nlm.nih.gov

Evaluation of five decontamination methods for filtering facepiece respirators - PubMed

Evaluation of five decontamination methods for filtering facepiece respirators

Dennis J Viscusi et al. Ann Occup Hyg. 2009 Nov.

Abstract

Concerns have been raised regarding the availability of National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One possible strategy to mitigate a respirator shortage is to reuse FFRs following a biological decontamination process to render infectious material on the FFR inactive. However, little data exist on the effects of decontamination methods on respirator integrity and performance. This study evaluated five decontamination methods [ultraviolet germicidal irradiation (UVGI), ethylene oxide, vaporized hydrogen peroxide (VHP), microwave oven irradiation, and bleach] using nine models of NIOSH-certified respirators (three models each of N95 FFRs, surgical N95 respirators, and P100 FFRs) to determine which methods should be considered for future research studies. Following treatment by each decontamination method, the FFRs were evaluated for changes in physical appearance, odor, and laboratory performance (filter aerosol penetration and filter airflow resistance). Additional experiments (dry heat laboratory oven exposures, off-gassing, and FFR hydrophobicity) were subsequently conducted to better understand material properties and possible health risks to the respirator user following decontamination. However, this study did not assess the efficiency of the decontamination methods to inactivate viable microorganisms. Microwave oven irradiation melted samples from two FFR models. The remainder of the FFR samples that had been decontaminated had expected levels of filter aerosol penetration and filter airflow resistance. The scent of bleach remained noticeable following overnight drying and low levels of chlorine gas were found to off-gas from bleach-decontaminated FFRs when rehydrated with deionized water. UVGI, ethylene oxide (EtO), and VHP were found to be the most promising decontamination methods; however, concerns remain about the throughput capabilities for EtO and VHP. Further research is needed before any specific decontamination methods can be recommended.

PubMed Disclaimer

Figures

Fig. 1.
Fig. 1.

N95 FFR average initial sodium chloride filter aerosol penetration versus temperature. Each data point represents the average initial penetration of three samples (n = 3), unless otherwise noted. ‘A’ indicates five SN95-D FFRs melted, one at 100°C, two at 110°C, and two at 120°C and could not be penetration or airflow resistance tested.

Fig. 2.
Fig. 2.

P100 FFR average initial sodium chloride filter aerosol penetration versus temperature. Each data point represents the average initial penetration of three samples (n = 3).

Fig. 3.
Fig. 3.

Chlorine off-gassing of FFRs after 30 min submersion in bleach (tested wet).

Fig. 4.
Fig. 4.

Chlorine off-gassing of FFRs submerged in bleach (dried overnight then rinsed with deionized water and tested wet).

Similar articles

Cited by

References

    1. 3M. 3M Steri-Vac ethylene oxide sterilization systems and accessories. St Paul, MN: 3M Inc; 2007. Available at http://www.3M.com/medicalspecialties. Accessed 24 March 2009.
    1. Advanced Sterilization Products. STERRAD® 100S. 2007. Available at http://www.sterrad.com/Products_&_Services/STERRAD/STERRAD_100S/Literatu.... Accessed 24 March 2009.
    1. Angehrn M. Ultraviolet disinfection of water. Aqua. 1984;2:109–15.
    1. Bailar JC, Brosseau LM, Cohen HJ, et al. Reusability of facemasks during an influenza pandemic. Washington, DC: Institute of Medicine, National Academies Press; 2006.
    1. CDC. Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care facilities. MMWR Recomm Rep. 1994;43:1–132. - PubMed

Publication types