Protein phosphorylation stoichiometry by simultaneous ICP-QMS determination of phosphorus and sulfur oxide ions: a multivariate optimization of plasma operating conditions - PubMed
- ️Fri Jan 01 2010
. 2010 Feb 15;80(4):1513-25.
doi: 10.1016/j.talanta.2009.06.082. Epub 2009 Jul 10.
Affiliations
- PMID: 20082809
- DOI: 10.1016/j.talanta.2009.06.082
Protein phosphorylation stoichiometry by simultaneous ICP-QMS determination of phosphorus and sulfur oxide ions: a multivariate optimization of plasma operating conditions
Domenico Ciavardelli et al. Talanta. 2010.
Abstract
Molecular mass spectrometry (MS) analysis of protein phosphorylation is partially limited by the molecular specie specificity of the analytical responses that might impair both qualitative and quantitative performances. Elemental MS, such as inductively coupled plasma mass spectrometry (ICP-MS) can overcome these drawbacks; in fact, analytical performance is theoretically independent of the molecular structure of a target analyte naturally containing the elements of interest. Nevertheless, isobaric interferences derived from sample matrix and laboratory environment can hinder the quantitative determination of both phosphorus (P) and sulfur (S) as (31)P(+) and (32)S(+) by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) under standard plasma conditions. These interferences may be overcome by quantifying P and S as oxide ions (31)P(16)O(+) and (32)S(16)O(+), respectively. In this study, we present a systematic investigation on the effect of plasma instrumental conditions on the oxide ion responses by a design of experiment approach for the simultaneous ICP-QMS determination of P and S ((31)P(16)O(+) and (32)S(16)O(+), respectively) in protein samples without the use of dynamic reaction, collision reaction cells or pre-addition of oxygen as reactant gas in the torch. The proposed method was evaluated in terms of limit of detection, limit of quantification, linearity, repeatability, and trueness. Moreover, detection and quantification capabilities of the optimized method were compared to the standard plasma mode for determination of (31)P(+) and (34)S(+). Spectral and non-spectral interferences affecting the quantification of (31)P(+), (31)P(16)O(+) and (32)S(16)O(+) were also studied. The suitability of inorganic elemental standards for P and S quantification in proteins was assessed. The method was applied to quantify the phosphorylation stoichiometry of commercially available caseins (bovine beta-casein, native and dephosphorylated alpha-casein) and results were confirmed by Matrix Assisted Laser Desorption Ionization Time of Flight MS analysis. We demonstrate that ICP-QMS, by quantifying P and S as oxide ions, was able to accurately calculate the degree of phosphorylation of beta-casein and alpha-casein and to detect specific partial enzymatic dephosphorylation. The collected results might lead to further development of ICP-QMS interfaces optimized for protein phosphorylation studies and for proteomics investigations.
(c) 2009 Elsevier B.V. All rights reserved.
Similar articles
-
Becker JS, Zoriy M, Becker JS, Pickhardt C, Damoc E, Juhacz G, Palkovits M, Przybylski M. Becker JS, et al. Anal Chem. 2005 Sep 15;77(18):5851-60. doi: 10.1021/ac0506579. Anal Chem. 2005. PMID: 16159114
-
Isotope ratio determination in boron analysis.
Sah RN, Brown PH. Sah RN, et al. Biol Trace Elem Res. 1998 Winter;66(1-3):39-53. doi: 10.1007/BF02783124. Biol Trace Elem Res. 1998. PMID: 10050906 Review.
-
El Balkhi S, Poupon J, Trocello JM, Massicot F, Woimant F, Laprévote O. El Balkhi S, et al. Anal Chem. 2010 Aug 15;82(16):6904-10. doi: 10.1021/ac101128x. Anal Chem. 2010. PMID: 20704379
-
Becker JS, Jakubowski N. Becker JS, et al. Chem Soc Rev. 2009 Jul;38(7):1969-83. doi: 10.1039/b618635c. Epub 2009 Apr 16. Chem Soc Rev. 2009. PMID: 19551177 Review.
Cited by
-
Post translational modifications of milk proteins in geographically diverse goat breeds.
Rout PK, Verma M. Rout PK, et al. Sci Rep. 2021 Mar 10;11(1):5619. doi: 10.1038/s41598-021-85094-9. Sci Rep. 2021. PMID: 33692444 Free PMC article.
-
Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.
Hecht ES, Oberg AL, Muddiman DC. Hecht ES, et al. J Am Soc Mass Spectrom. 2016 May;27(5):767-85. doi: 10.1007/s13361-016-1344-x. Epub 2016 Mar 7. J Am Soc Mass Spectrom. 2016. PMID: 26951559 Free PMC article. Review.