A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement - PubMed
A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement
Pauwel Goethals et al. J Clin Monit Comput. 2014 Apr.
Abstract
We present a new device for verifying endotracheal tube (ETT) position that uses specialized sensors intended to distinguish anatomical features of the trachea and esophagus. This device has the potential to increase the safety of resuscitation, surgery, and mechanical ventilation and decrease the morbidity, mortality, and health care costs associated with esophageal intubation and unintended extubation by potentially improving the process and maintenance of endotracheal intubation. The device consists of a tactile sensor connected to the airway occlusion cuff of an ETT. It is intended to detect the presence or absence of tracheal rings immediately upon inflation of the airway occlusion cuff. The initial study detailed here verifies that a prototype device can detect contours similar to tracheal rings in a tracheal model.
Similar articles
-
Uya A, Spear D, Patel K, Okada P, Sheeran P, McCreight A. Uya A, et al. Acad Emerg Med. 2012 Mar;19(3):361-4. doi: 10.1111/j.1553-2712.2012.01306.x. Acad Emerg Med. 2012. PMID: 22435870
-
Magnetic endotracheal tube imaging device.
Wichakool W, Pierquet B, Durand K, Hsu B, Sheridan R, Ma H. Wichakool W, et al. Annu Int Conf IEEE Eng Med Biol Soc. 2008;2008:985-8. doi: 10.1109/IEMBS.2008.4649320. Annu Int Conf IEEE Eng Med Biol Soc. 2008. PMID: 19162823
-
Tracheal palpation to assess endotracheal tube depth: an exploratory study.
McKay WP, Klonarakis J, Pelivanov V, O'Brien JM, Plewes C. McKay WP, et al. Can J Anaesth. 2014 Mar;61(3):229-34. doi: 10.1007/s12630-013-0079-4. Epub 2013 Nov 21. Can J Anaesth. 2014. PMID: 24259250
-
A review of force and resonance sensors used in the clinical study of tissue properties.
Yousuf MA, Asiyanbola BA. Yousuf MA, et al. Proc Inst Mech Eng H. 2013 Dec;227(12):1333-40. doi: 10.1177/0954411913493722. Epub 2013 Sep 18. Proc Inst Mech Eng H. 2013. PMID: 24048077 Review.
-
The esophageal-tracheal double-lumen airway: rescue for the difficult airway.
Smally A. Smally A. AANA J. 2007 Apr;75(2):129-34. AANA J. 2007. PMID: 17471885 Review.
Cited by
-
Design and Control of a Mechatronic Tracheostomy Tube for Automated Tracheal Suctioning.
Do TN, Seah TET, Phee SJ. Do TN, et al. IEEE Trans Biomed Eng. 2016 Jun;63(6):1229-1238. doi: 10.1109/TBME.2015.2491327. Epub 2015 Oct 15. IEEE Trans Biomed Eng. 2016. PMID: 26485352 Free PMC article.
-
Intra-tracheal multiplexed sensing of contact pressure and perfusion.
Correia R, Gadsby B, Korposh S, Norris AM, Hayes-Gill BR, Sinha R, Hardman JG, Gardner DS, Talbot S, Harvey D, McGlashan J, Morgan SP. Correia R, et al. Biomed Opt Express. 2021 Dec 3;13(1):48-64. doi: 10.1364/BOE.442165. eCollection 2022 Jan 1. Biomed Opt Express. 2021. PMID: 35154853 Free PMC article.
-
Journal of clinical monitoring and computing 2014 end of year summary: respiration.
Karbing DS, Rees SE, Jaffe MB. Karbing DS, et al. J Clin Monit Comput. 2015 Apr;29(2):209-15. doi: 10.1007/s10877-015-9676-9. Epub 2015 Mar 4. J Clin Monit Comput. 2015. PMID: 25735264 Review. No abstract available.
-
Continuous monitoring of endotracheal tube position with near infrared light.
Lu T, Khampang P, Beydoun A, Berezovsky A, Rohde R, Hong W, Yu B, Kerschner JE. Lu T, et al. J Biomed Opt. 2024 Mar;29(3):035001. doi: 10.1117/1.JBO.29.3.035001. Epub 2024 Mar 12. J Biomed Opt. 2024. PMID: 38476221 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources