HIGH LIFE: High altitude fatalities led to pulse oximetry - PubMed
- ️Fri Jan 01 2016
Review
. 2016 Jan 15;120(2):236-43.
doi: 10.1152/japplphysiol.00476.2015. Epub 2015 Aug 6.
Affiliations
- PMID: 26251514
- DOI: 10.1152/japplphysiol.00476.2015
Free article
Review
HIGH LIFE: High altitude fatalities led to pulse oximetry
John W Severinghaus. J Appl Physiol (1985). 2016.
Free article
Abstract
In 1875, Paul Bert linked high altitude danger to the low partial pressure of oxygen when 2 of 3 French balloonists died euphorically at about 8,600 m altitude. World War I fatal crashes of high altitude fighter pilots led to a century of efforts to use oximetry to warn pilots. The carotid body, discovered in 1932 to be the hypoxia detector, led to most current physiologic understanding of the body's respiratory responses to hypoxia and CO2. The author describes some of his UCSF group's work: In 1963, we reported both the brain's ventral medullary near-surface CO2 (and pH) chemosensors and the role of cerebrospinal fluid in acclimatization to altitude. In 1966, we reported the effect of altitude on cerebral blood flow and later the changes of carotid body sensitivity at altitude and the differences in natives of high altitude. In 1973, pulse oximetry was invented when Japanese biophysicist Takuo Aoyagi read and applied to pulses a largely forgotten 35-year-old discovery by English medical student J. R. Squire of a method of computing oxygen saturation from red and infrared light passing through both perfused and blanched tissue.
Copyright © 2016 the American Physiological Society.
Similar articles
-
Bloch KE, Latshang TD, Turk AJ, Hess T, Hefti U, Merz TM, Bosch MM, Barthelmes D, Hefti JP, Maggiorini M, Schoch OD. Bloch KE, et al. Am J Respir Crit Care Med. 2010 Aug 15;182(4):562-8. doi: 10.1164/rccm.200911-1694OC. Epub 2010 May 4. Am J Respir Crit Care Med. 2010. PMID: 20442435 Clinical Trial.
-
Takuo Aoyagi: discovery of pulse oximetry.
Severinghaus JW. Severinghaus JW. Anesth Analg. 2007 Dec;105(6 Suppl):S1-S4. doi: 10.1213/01.ane.0000269514.31660.09. Anesth Analg. 2007. PMID: 18048890
-
The correct measurement of oxygen saturation at high altitude.
Tannheimer M, Lechner R. Tannheimer M, et al. Sleep Breath. 2019 Dec;23(4):1101-1106. doi: 10.1007/s11325-019-01784-9. Epub 2019 Jan 30. Sleep Breath. 2019. PMID: 30701422
-
Cerebral blood flow at high altitude.
Ainslie PN, Subudhi AW. Ainslie PN, et al. High Alt Med Biol. 2014 Jun;15(2):133-40. doi: 10.1089/ham.2013.1138. High Alt Med Biol. 2014. PMID: 24971767 Review.
-
Pulse oximetry at high altitude.
Luks AM, Swenson ER. Luks AM, et al. High Alt Med Biol. 2011 Summer;12(2):109-19. doi: 10.1089/ham.2011.0013. High Alt Med Biol. 2011. PMID: 21718156 Review.
Cited by
-
Tribute to Dr. Takuo Aoyagi, inventor of pulse oximetry.
Miyasaka K, Shelley K, Takahashi S, Kubota H, Ito K, Yoshiya I, Yamanishi A, Cooper JB, Steward DJ, Nishida H, Kiani J, Ogino H, Sata Y, Kopotic RJ, Jenkin K, Hannenberg A, Gawande A. Miyasaka K, et al. J Anesth. 2021 Oct;35(5):671-709. doi: 10.1007/s00540-021-02967-z. Epub 2021 Aug 2. J Anesth. 2021. PMID: 34338865 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources