Inflating one's own cuff does not increase self-recorded blood pressure - PubMed
Inflating one's own cuff does not increase self-recorded blood pressure
D P Veerman et al. J Hypertens Suppl. 1988 Dec.
Abstract
To determine whether the muscular activity required to inflate a blood pressure cuff for self-recording influences the blood pressure at the instant of the subsequent measurement, finger blood pressure was recorded continuously during cuff inflation. Ten normotensive and seven untreated hypertensive subjects used their dominant hands to inflate, in 5 s, an occluding cuff on the same arm up to 200 mmHg. Blood pressure in the middle finger of the other arm was measured continuously by the Finapres device. Korotkoff sounds were determined by a microphone in the arm cuff, and the speed of deflation was kept constant by the investigator at 2-3 mmHg/s. Systolic pressure rose at the onset of inflation, with an average peak of 13 +/- 6 (s.d.) and 12 +/- 8 mmHg above baseline in the normotensive and hypertensive subjects, respectively. Five seconds after the onset of deflation both systolic and diastolic pressures in both groups had returned to baseline levels. Thus, self-inflation of a blood pressure cuff allows a valid measurement of blood pressure provided the recommended guidelines are strictly followed.
Similar articles
-
Effects of cuff inflation on self-recorded blood pressure.
Veerman DP, van Montfrans GA, Wieling W. Veerman DP, et al. Lancet. 1990 Feb 24;335(8687):451-3. doi: 10.1016/0140-6736(90)90676-v. Lancet. 1990. PMID: 1968178 Clinical Trial.
-
Charmoy A, Würzner G, Ruffieux C, Hasler C, Cachat F, Waeber B, Burnier M. Charmoy A, et al. Blood Press Monit. 2007 Oct;12(5):275-80. doi: 10.1097/MBP.0b013e3282c9ac9a. Blood Press Monit. 2007. PMID: 17890965 Clinical Trial.
-
Raising the arm before cuff inflation increases the loudness of Korotkoff sounds.
Verrij EA, Nieuwenhuizen L, Bos WJ. Verrij EA, et al. Blood Press Monit. 2009 Dec;14(6):268-73. doi: 10.1097/MBP.0b013e3283330a67. Blood Press Monit. 2009. PMID: 19881335
-
Optimal size of cuff bladder for indirect measurement of arterial pressure in adults.
Russell AE, Wing LM, Smith SA, Aylward PE, McRitchie RJ, Hassam RM, West MJ, Chalmers JP. Russell AE, et al. J Hypertens. 1989 Aug;7(8):607-13. doi: 10.1097/00004872-198908000-00002. J Hypertens. 1989. PMID: 2681407 Review.
Cited by
-
Sheshadri V, Tiwari AK, Nagappa M, Venkatraghavan L. Sheshadri V, et al. Anesth Essays Res. 2017 Jan-Mar;11(1):169-173. doi: 10.4103/0259-1162.181430. Anesth Essays Res. 2017. PMID: 28298779 Free PMC article.
-
Principles and techniques of blood pressure measurement.
Ogedegbe G, Pickering T. Ogedegbe G, et al. Cardiol Clin. 2010 Nov;28(4):571-86. doi: 10.1016/j.ccl.2010.07.006. Cardiol Clin. 2010. PMID: 20937442 Free PMC article. Review.