Quantitative measurement of portal blood flow in patients with chronic liver disease using an ultrasonic Duplex system consisting of a pulsed Doppler flowmeter and B-mode electroscanner - PubMed
- PMID: 6098510
- DOI: 10.1007/BF02793866
Quantitative measurement of portal blood flow in patients with chronic liver disease using an ultrasonic Duplex system consisting of a pulsed Doppler flowmeter and B-mode electroscanner
F Moriyasu et al. Gastroenterol Jpn. 1984 Dec.
Abstract
Portal blood flow (PBF) can be measured quantitatively using a B-mode combined pulsed Doppler (BCD) system. This system combines a real time B-mode linear type electroscanner and a pulsed Doppler (D-mode) flowmeter. Since both modes are displayed in realtime, Doppler blood flow signals can be retrieved at will from any depth. The blood flow velocity determined by the Doppler spectrogram and the vascular cross-sectional area measured from the B-mode tomographic image enables the quantitative calculation of blood flow volume. Using this system, PBF was measured quantitatively in 88 healthy adults, 54 patients with chronic hepatitis, 65 with cirrhosis of the liver, 27 with primary hepatoma and 12 with idiopathic portal hypertension (IPH). Results of PBF volume measurement were as follows: 889 +/- 284 ml/min (mean +/- S.D.) for healthy adults, 851 +/- 237 ml/min for patients with chronic hepatitis, 870 +/- 289 ml/min for cirrhosis of the liver, 966 +/- 375 ml/min for primary hepatoma and 1,047 +/- 381 ml/min for IPH. These preliminary results demonstrated that this ultrasonic Duplex system is clinically useful to determine the quantitative amount of PBF.
Similar articles
-
Shiraki S, Tsukada K, Ozeki N, Takeuchi T, Gotoh K, Noguchi Y, Okayama Y, Matsuba S, Ohhara H, Masuko K. Shiraki S, et al. Gastroenterol Jpn. 1988 Feb;23(1):37-43. doi: 10.1007/BF02918854. Gastroenterol Jpn. 1988. PMID: 2965048
-
Moriyasu F, Ban N, Kanematsu Y, Nishida O, Nakamura T, Sakai M, Uchino H, Miyake T. Moriyasu F, et al. Nihon Shokakibyo Gakkai Zasshi. 1984 Nov;81(11):2767-74. Nihon Shokakibyo Gakkai Zasshi. 1984. PMID: 6240553 Japanese. No abstract available.
-
Moriyasu F, Ban N, Nishida O, Nakamura T, Miyake T, Uchino H, Kanematsu Y, Koizumi S. Moriyasu F, et al. J Clin Ultrasound. 1986 Oct;14(8):579-88. doi: 10.1002/jcu.1870140802. J Clin Ultrasound. 1986. PMID: 2945835
-
Doppler ultrasound in diagnosis of liver tumor and portal hypertension.
Moriyasu F. Moriyasu F. Radiol Med. 1993 May;85(5 Suppl 1):44-55. Radiol Med. 1993. PMID: 8392742 Review.
-
Hepatoportal circulation and its clinical implications.
Reich T. Reich T. N Y State J Med. 1971 May 1;71(9):947-51. N Y State J Med. 1971. PMID: 4929519 Review. No abstract available.
Cited by
-
Wicklein S, Mühlberg W, Richter B, Sieber CC. Wicklein S, et al. Z Gerontol Geriatr. 2007 Feb;40(1):37-42. doi: 10.1007/s00391-007-0431-9. Z Gerontol Geriatr. 2007. PMID: 17318730
-
Ultrasonic Doppler duplex study of hemodynamic changes from portosystemic shunt operation.
Moriyasu F, Nishida O, Ban N, Nakamura T, Tamada T, Kawasaki T, Sakai M, Miyake T, Kumada K, Ozawa K, et al. Moriyasu F, et al. Ann Surg. 1987 Feb;205(2):151-6. doi: 10.1097/00000658-198702000-00009. Ann Surg. 1987. PMID: 2949715 Free PMC article.
-
Paquet KJ, Mercado MA, Klingele H, Klingele R. Paquet KJ, et al. Surg Endosc. 1991;5(4):204-8. doi: 10.1007/BF02653265. Surg Endosc. 1991. PMID: 1805399
-
Pathophysiology and epidemiology of portal hypertension.
Okumura H, Aramaki T, Katsuta Y. Okumura H, et al. Drugs. 1989;37 Suppl 2:2-12; discussion 47. doi: 10.2165/00003495-198900372-00003. Drugs. 1989. PMID: 2680428 Review.
-
Iwanaga T, Koyanagi N, Sugimachi K. Iwanaga T, et al. Jpn J Surg. 1987 Jan;17(1):58-9. doi: 10.1007/BF02470588. Jpn J Surg. 1987. PMID: 2952827
References
MeSH terms
LinkOut - more resources
Medical