Pulsatile flow in a model carotid bifurcation - PubMed
Comparative Study
. 1983 Jan-Feb;3(1):31-9.
doi: 10.1161/01.atv.3.1.31.
- PMID: 6824494
- DOI: 10.1161/01.atv.3.1.31
Comparative Study
Pulsatile flow in a model carotid bifurcation
D N Ku et al. Arteriosclerosis. 1983 Jan-Feb.
Abstract
Pulsatile flow in an in vitro model of the human carotid bifurcation was studied by flow visualization using hydrogen bubble techniques. A glass model was constructed after determining an average geometry from 57 biplanar angiograms of 22 subjects ranging from 34 to 77 years of age. The flow pulse used was a half-sine wave superimposed upon a mean flow. Maximum and minimum values of the instantaneous Reynolds number were 1200 and 400, respectively, based upon conditions in the common carotid model artery; the frequency parameter was 6.0. The division of flow into the internal external branches was 70:30. Visualization by hydrogen bubbles demonstrated significant deviations from steady flow behavior. Flow separated in the carotid sinus over the entire cycle, but the location and extent of separation varied strongly. The direction of flow near the walls of the model changed sharply during the cycle except for the region near the apex of the bifurcation where the orientation of streaklines was more nearly unidirectional at all times. Bubbles entering the separated flow region tended to remain entrapped there for several cycles. Rapid dispersion of bubbles occurred in the internal branch near the end of systole, suggesting the presence of flow disorder. The location of low wall shear stresses, directionally varying stresses, and longer residence times for fluid elements appears to coincide with the localization of early atheromatous plaques in human carotid specimens.
Similar articles
-
Ku DN, Giddens DP, Zarins CK, Glagov S. Ku DN, et al. Arteriosclerosis. 1985 May-Jun;5(3):293-302. doi: 10.1161/01.atv.5.3.293. Arteriosclerosis. 1985. PMID: 3994585
-
Zarins CK, Giddens DP, Bharadvaj BK, Sottiurai VS, Mabon RF, Glagov S. Zarins CK, et al. Circ Res. 1983 Oct;53(4):502-14. doi: 10.1161/01.res.53.4.502. Circ Res. 1983. PMID: 6627609
-
Perktold K, Rappitsch G. Perktold K, et al. J Biomech. 1995 Jul;28(7):845-56. doi: 10.1016/0021-9290(95)95273-8. J Biomech. 1995. PMID: 7657682
-
Liepsch D, Pflugbeil G, Matsuo T, Lesniak B. Liepsch D, et al. Clin Hemorheol Microcirc. 1998 Apr;18(1):1-30. Clin Hemorheol Microcirc. 1998. PMID: 9653582 Review.
-
Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries.
Glagov S, Zarins C, Giddens DP, Ku DN. Glagov S, et al. Arch Pathol Lab Med. 1988 Oct;112(10):1018-31. Arch Pathol Lab Med. 1988. PMID: 3052352 Review.
Cited by
-
Basic flow structure in saccular aneurysms: a flow visualization study.
Steiger HJ, Poll A, Liepsch D, Reulen HJ. Steiger HJ, et al. Heart Vessels. 1987;3(2):55-65. doi: 10.1007/BF02058520. Heart Vessels. 1987. PMID: 3500943
-
Conklin BS, Vito RP, Chen C. Conklin BS, et al. World J Surg. 2007 Apr;31(4):733-43. doi: 10.1007/s00268-006-0735-8. World J Surg. 2007. PMID: 17372666
-
Hemodynamically driven stent strut design.
Jiménez JM, Davies PF. Jiménez JM, et al. Ann Biomed Eng. 2009 Aug;37(8):1483-94. doi: 10.1007/s10439-009-9719-9. Epub 2009 May 27. Ann Biomed Eng. 2009. PMID: 19472055 Free PMC article.
-
Characteristics of pulsatile flows in curved stenosed channels.
Hong H, Yeom E, Ji HS, Kim HD, Kim KC. Hong H, et al. PLoS One. 2017 Oct 19;12(10):e0186300. doi: 10.1371/journal.pone.0186300. eCollection 2017. PLoS One. 2017. PMID: 29049327 Free PMC article.
-
Computer-controlled positive displacement pump for physiological flow simulation.
Holdsworth DW, Rickey DW, Drangova M, Miller DJ, Fenster A. Holdsworth DW, et al. Med Biol Eng Comput. 1991 Nov;29(6):565-70. doi: 10.1007/BF02446086. Med Biol Eng Comput. 1991. PMID: 1813750
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous