Stockman and Sharpe luminosity function
Sharpe, Stockman, Jagla & Jägle (2005) 2-deg V*(l) luminous efficiency function
Units |
0.1 nm steps |
1 nm steps |
5 nm steps |
Quantal (log) |
|||
Energy (log) |
|||
Energy (linear) |
Data key
Columns
Quantal
Logarithmic
- Wavelength (nm)
- log 2-deg photopic luminous efficiency, V2*(l)
Energy
Logarithmic
- Wavelength (nm)
- log 2-deg photopic luminous efficiency, V2e*(l)
Linear
- Wavelength (nm)
- 2-deg photopic luminous efficiency, V2e*(l)
Notes
Based on the linear combination of the Stockman and Sharpe (2000) M- and L-cone spectral sensitivities that best fits experimentally-determined 25-Hz, 2° diameter, heterochromatic (minimum) flicker photometric data obtained from 40 observers (35 males, 5 females) of known genotype, 22 with the serine variant L(ser180), 16 with the alanine L(ala180) variant and 2 with both variants of the L-cone photopigment. The matches, from 425 to 675 nm in 5-nm steps, were made on a 3 log troland xenon white (correlated color temperature of 5586 K, but tritanopically metameric with CIE D65 standard daylight for the Stockman & Sharpe (2000) L- and M-cone fundamentals) adapting field of 16° angular subtense, relative to a 560 nm standard. Both the reference standard and test lights were kept near flicker threshold so that, in the region of the targets, the total retinal illuminance averaged 3.19 log trolands. The new function is extrapolated to wavelengths shorter than 425 nm and longer than 675 nm using the Stockman & Sharpe (2000) cone fundamentals. The quantal luminous efficiency function is:
or
relative to the quantal
cone fundamentals and
having unity peak sensitivities. Functions are
tabulated at 0.1, 1 or 5 nm steps. The 0.1 and 1 nm functions were
obtained by the interpolation of the 5 nm functions using a cubic spline. Functions are normalized to peak at unity at
the nearest 0.1 nm step. The lmax for
quantal efficiencies is 545.6 nm.
The same function, but energy based, and
given in terms of the energy based
cone fundamentals and
renormalized to unity peak sensitivities:
or
The different weight simply reflects the unity renormalization required after the cone fundamentals are converted from quanta to energy units. The lmax for energy-based efficiencies is 555.5 nm.
NB This is a update of the preliminary estimate of V2*(l), given previously in Stockman & Sharpe (2000) and previously tabulated here. The preliminary estimate, which had an L-cone weight of 1.50, was based on the first 22 of the 40 observers used to obtain the final estimate.
References
Stockman, A., & Sharpe, L. T. (2000). Spectral sensitivities of the middle- and long-wavelength sensitive cones derived from measurements in observers of known genotype. Vision Research, 40, 1711-1737.
Sharpe, L. T., Stockman, A., Jagla, W. & Jägle, H.(2005). A luminous efficiency function, V*(l), for daylight adaptation. Journal of Vision, 5, 948-968.